Product Details:
|
Material: | Polypropylene/ Glass Fiber | Removal Rating: | 1Um -70 Um |
---|---|---|---|
Suggestion Design Flow: | 4 M³/h | Suggestion Pressure For Filter Replacement: | 2.5Bar@20℃ |
Flow Type: | Outside To Inside | Max. Operating Temperature: | 85 ℃ |
APPlication: | Power Plant Condensation Water Filtration | Filter Area: | 6.5 Square Meter |
Bottom Thread: | M6, M8, M10, 3/8 | ||
Highlight: | 1um backwash cartridge filter,M6 backwash cartridge filter,1um melt blown polypropylene filter |
Ordering Information
PHFZ PP 0500 70 III Z2 W
Series | Media | Micron | Length | Structure | Connection Thread | End Tread |
PHFZ | PP=Polypropylene |
0100=1.0μm 0400=4.0μm 1000=10μm |
60=60" 70=70" |
I=7Part(φ69) II=4+3(φ65) III=3+1(φ69) |
Z1=1 1/2"-12 Z2=M33×1.5 |
W1=M8 W2=M10 W3=M6 W4=3/8 |
Material Constructions
Filter Media | Polypropylene (PP) |
Cage/Core/End cap | Polypropylene (PP) |
Accessories (nut, screw) | SS304 |
Performance
Maximum Operating Temperature | 85℃ |
Maximum Operating Differential Pressure | 3.0bar/65℃ |
Filtration Area | 6.5㎡ |
Flow Rate |
3.5-4.5m3/h(Design) 3.9m3/h(Recommend) |
Inlet water quality | <2000ppb |
Backwash water or gas: Under the pressure of 1.36-2.1bar, the backwash water of each filter cartridge is 0.45-0.65m3/h, backwash gas 3.4-5m3/h, can achieve the ideal effect.
600MW supercritical units and 1000MW ultra-supercritical units, respectively recommended use 4μm and 1μm 70" filter cartridge, when debugging recommend 10μm filter cartridge for start-up.
Contact Person: Lucy
Tel: 86-21-57718597