Product Details:
|
| Highlight: | V-Bank Compact Air Filter,Mini-Pleated V-Bank Filter,Customizable Efficiency Air Filter |
||
|---|---|---|---|
A rigid-frame, mini-pleated V-bank compact air filter engineered for high-efficiency fine dust removal in HVAC systems, air handling units (AHU), cleanrooms and industrial ventilation. The V-shaped media pack delivers a large filtration area inside a shallow installation depth — high airflow, low pressure drop and long service life in one compact footprint.
The V-bank compact air filter is designed for high-efficiency air filtration in HVAC systems, air handling units, cleanrooms and industrial ventilation equipment. The filter uses several mini-pleated media packs arranged in a V-shaped structure inside a rigid frame. This design provides a large filtration area within a relatively small installation depth, making it suitable for systems that require high airflow and better particle removal performance.
Compared with a traditional pocket filter, the compact V-bank filter provides a more rigid structure and a higher filtration area. It is normally used at the medium-to-high efficiency or final filtration stage, depending on the filter media and efficiency grade. In practical applications, it can be installed after a pre-filter to remove fine dust and airborne particles before the air enters production areas, cleanrooms or sensitive equipment.
A typical air filtration process can be arranged as:
For systems with higher cleanliness requirements, the V-bank filter can also be used before a final HEPA filter to reduce the dust load and help extend HEPA filter service life.
Mini-pleated synthetic or glass-fibre media is folded into a series of shallow pleats, separated by hot-melt beads so that every pleat stays open and the airflow stays evenly distributed. Several of these pleat packs are then set at an angle to each other inside a rigid frame, forming the V-shaped geometry that gives the filter its name.
Because the media is folded rather than flat, a single 292 mm or 592 mm module can carry two to three times the media area of a comparable flat panel filter. More media area means a lower face velocity for the same airflow, which keeps the initial pressure drop low, raises dust-holding capacity and delays the point at which the filter has to be replaced.
The rigid frame keeps the pleat packs in position under high airflow, so the filter does not collapse, flutter or shed media — a common weak point of soft pocket filters in high-velocity AHU installations. The result is stable efficiency over the whole service interval, not only when the filter is new.
V-bank compact filters are commonly used in central air-conditioning systems, pharmaceutical factories, electronics plants, laboratories, food and beverage production areas, hospitals and other facilities where better indoor air quality is required.
In commercial HVAC systems the filter can be installed inside the AHU to remove finer airborne dust before the air is supplied to offices, hotels, shopping malls or other occupied areas. In industrial factories, it helps reduce contamination entering production areas and protects cooling coils, ducts and downstream filters.
In pharmaceutical, electronics and cleanroom ventilation systems, compact filters are often used as an intermediate or high-efficiency filtration stage. Their large filtration area allows them to handle relatively high airflow while maintaining a reasonable pressure drop. For food and beverage workshops, the filter is used in the ventilation system rather than for direct product filtration — it helps keep the production environment cleaner by reducing airborne dust and particles.
| Design Feature | What It Means in Operation |
|---|---|
| Mini-pleated V-bank media | More filter media inside the same frame size — larger effective filtration area, higher dust-holding capacity and longer replacement intervals. |
| Rigid frame construction | The filter holds its shape under high airflow, resists collapse and media shedding, and stays sealed against the holding frame. |
| Low initial pressure drop | Lower face velocity for the same airflow reduces fan energy consumption and keeps operating cost predictable. |
| Stable efficiency over service life | Even airflow distribution through the pleat packs gives consistent particle retention from first installation to final pressure drop. |
| Shallow installation depth | Retrofits into existing AHU filter tracks where a deep pocket filter or bag filter will not fit. |
| Selectable efficiency grades | F7, F8, F9 and E10–E12 classes can be specified to match the required air cleanliness and downstream HEPA stage. |
| Custom frame and media options | Galvanized steel, aluminium or plastic frames with synthetic or glass-fibre media to suit the operating environment. |
The V-shaped arrangement allows more filter media to be installed inside the same frame size, increasing effective filtration area and dust-holding capacity. The rigid construction also helps the filter maintain its shape under high airflow conditions. Mini-pleated filter media provides stable particle retention and even airflow distribution. Depending on the application, the frame can be made of galvanized steel, aluminum, plastic or other suitable materials. Different efficiency grades, dimensions and airflow capacities can be selected according to the HVAC system design.
| Parameter | Specification |
|---|---|
| Product Name | V-Bank Compact Air Filter |
| Filter Type | Compact / V-Bank Air Filter |
| Filter Media | Synthetic Fiber, Glass Fiber or Customized |
| Frame Material | Galvanized Steel, Aluminum, Plastic or Customized |
| Structure | Mini-Pleated V-Bank |
| Efficiency Grade | Customized |
| Typical Efficiency | F7, F8, F9, E10, E11, E12 or Customized |
| Filter Size | Standard or Customized |
| Airflow | According to Filter Size and Efficiency |
| Main Function | Fine Airborne Particle Removal |
| Installation | HVAC, AHU and Ventilation Systems |
| Application | Commercial Buildings, Cleanrooms, Pharmaceutical, Electronics, Food and Beverage |
| Separator | Hot-Melt Bead Separator Between Pleats |
| Face Guard | Protective Mesh or Grid on Both Sides |
| Gasket | Optional Foam or EPDM Gasket for Frame Sealing |
| Efficiency Standard | EN 779, ISO 16890 or EN 1822 Classification on Request |
| Packaging | Export Standard Packaging, Carton with Inner Protection |
Dimensions, V-pack quantity, media type and efficiency grade are project-specific. Please confirm the required efficiency standard (EN 779 class, ISO 16890 ePM1 / ePM2.5 group, or EN 1822 class) before ordering so that the correct media and pressure-drop curve are supplied.
For correct selection, three values should be confirmed together: the required airflow, the target efficiency grade and the acceptable final pressure drop. A filter chosen only by frame size may operate at an unnecessarily high face velocity, which increases pressure drop and shortens service life.
Install the filter with the airflow arrow pointing in the direction of the air stream, and make sure the frame seats fully against the gasket so that no air bypasses around the filter. Bypass leakage is the most common reason a correctly rated filter fails to deliver the expected air cleanliness in a cleanroom or AHU.
Replacement is normally determined by differential pressure, airflow and system requirements. As dust accumulates, the pressure drop across the filter increases. When the pressure drop reaches the recommended final value — typically two to three times the initial reading — the filter should be replaced. Most high-efficiency compact filters are designed as replaceable items rather than washable filters, since cleaning may damage the media or change the filtration performance.
It is mainly used for fine or high-efficiency air filtration in HVAC and air handling systems. It removes smaller airborne particles that pass through coarse or medium-efficiency pre-filters and helps improve the cleanliness of supply air.
A pocket filter uses flexible filter bags, while a V-bank compact filter uses rigid mini-pleated media packs. The V-bank design usually provides a larger filtration area in a compact space and can be selected for higher efficiency grades and higher airflow applications.
It depends on the efficiency grade. Some compact filters can be used as final filters in general ventilation systems, while higher cleanliness applications may still require a HEPA filter downstream. The correct configuration should be selected according to the required air cleanliness.
Yes. A V-bank compact filter is often installed before a HEPA filter to capture fine dust first. This reduces the amount of contamination reaching the HEPA filter and can extend its service life.
The filter can be supplied in different efficiency grades, such as F7, F8, F9 and higher efficiency classes depending on the filter media and system requirement. If the project follows ISO 16890 or EN 1822, the corresponding efficiency should be confirmed according to the required standard.
The V-shaped arrangement increases the amount of filter media that can fit inside the frame. This gives the filter a larger effective filtration area, higher dust-holding capacity and better airflow performance than a simple flat filter.
It is normally installed inside an AHU, ventilation unit or cleanroom air-conditioning system. Common positions include after a pre-filter or pocket filter and before the final air supply section.
Yes. Width, height, depth, number of V-shaped media packs, frame material and efficiency grade can be customized according to the existing equipment.
Replacement is normally determined by differential pressure, airflow and system requirements. As dust accumulates, the pressure drop across the filter increases. When it reaches the recommended final pressure drop, the filter should be replaced.
Yes. It is commonly used in the ventilation and air-conditioning systems of pharmaceutical, electronics and other controlled production environments. The actual efficiency grade should be selected according to the required room cleanliness and downstream filtration system.
Please provide the filter dimensions, required efficiency grade, airflow, frame material, operating environment and quantity. If replacing an existing filter, a photo, model number or pressure-drop requirement can also help with selection.
Most high-efficiency compact filters are designed as replaceable filters rather than washable filters. Cleaning may damage the filter media or change its filtration performance, so replacement is normally recommended once the final pressure drop is reached.
Shanghai Pullner Filtration Technology Co., Ltd.
Established: 2013
Shanghai Pullner Filtration Technology Co., Ltd., established in 2013, is a professional manufacturer of filter cartridges and filtration solutions.
With a 15,000m² production facility, 20+ production lines, advanced testing laboratories, and experienced R&D teams, Pullner provides high-performance filtration products for Microelectronics, Biopharmaceuticals, Food & Beverage, Petrochemical, Water Treatment, Power Generation, and other industries.
Certified with ISO 9001, ISO 14001, and ISO 45001, Pullner is committed to delivering reliable and innovative filtration solutions to customers worldwide.
A1: Manufacturer: Shanghai Pullner Filtration Technology Co., Ltd. / Brand: Pullner.
A2: Yes. We can provide 1-2 free samples for evaluation. Buyers only cover shipping. (Free samples are typically supported for future formal orders.)
A3: Usually 5-10 working days for standard products, depending on order quantity.
A4: Standard products are nominal. Absolute-rated filters can be customized based on your application.
A5: Compatible replacements include major brands such as PALL, 3M, PARKER, and others.
A6: Standard MOQ is 1 piece (factory direct). For certain models or customized specs, MOQ may vary.
Contact Person: Hudarm
Tel: 86-18311506837
Fax: 86-021-57711314
Overall Rating